1. Automation/Motion Controls For Sale
  2. sku: 15900996190154881
  3. TELEMECANIQUE LB1-LC03M13

TELEMECANIQUE LB1-LC03M13 Overload Relay Trip 6.3 10A

Lb1-lc03m13 Telemecanique Overload Relay 6.3 - 10a Trip Current

( Brand: Telemecanique ), ( Manufacturer Part Number: LB1-LC03M13 )

Review TELEMECANIQUE Overload Relay 6.3 10a Trip Current

The **Telemecanique LB1-LC03M13 Overload Relay** is a high-performance, compact motor protection device designed to safeguard three-phase induction motors and other electrical loads from thermal overloads, ensuring reliable operation and extending equipment lifespan. Part of Schneider Electric s robust LB1 series, this overload relay combines precision engineering with user-friendly features to deliver dependable protection in industrial, commercial, and residential applications. With a **rated current of 6.3A** and a **trip current of 10A**, it is specifically tailored for motors in the lower to mid-range power spectrum, making it ideal for applications such as pumps, compressors, conveyors, and HVAC systems where consistent protection is critical. The **LC03M13 variant** incorporates a **thermal overload protection mechanism** with a **bimetallic element**, which responds to sustained overcurrent conditions by disconnecting the circuit before damage occurs. This thermal response ensures gradual tripping based on the motor s heat buildup, preventing sudden failures while allowing for minor temporary overloads, such as those caused by starting currents or mechanical overloads.

One of the standout features of this overload relay is its **adjustable trip setting**, allowing operators to fine-tune the protection curve to match the specific requirements of the connected motor. The **M13 designation** indicates a **class 10 overload relay**, which provides a **standard inverse-time characteristic**, ensuring that the relay trips more slowly for smaller overloads and more quickly for severe overcurrents, thus optimizing protection without unnecessary disruptions. The device is equipped with a **mechanical trip indicator**, which clearly signals when the relay has tripped, enabling quick troubleshooting and reset operations. Additionally, the **LC03M13 model** features a **manual reset mechanism**, allowing for safe and convenient re-energization after a fault has been addressed. This manual reset function enhances operational efficiency by reducing downtime while maintaining safety standards.

Constructed with **durable materials**, the LB1-LC03M13 overload relay is designed to withstand harsh industrial environments, offering **IP20 protection** against solid objects and limited water ingress. Its **compact and modular design** allows for easy integration into existing electrical panels, making it a versatile choice for both new installations and retrofits. The relay s **low-profile mounting** and **standard DIN rail compatibility** further simplify installation, ensuring a clean and organized control panel layout. Furthermore, the **Telemecanique LB1 series** is known for its **high reliability and long service life**, with components engineered to minimize wear and tear over extended periods of use. This reliability is further supported by Schneider Electric s reputation for quality, backed by comprehensive technical documentation and customer support.

Beyond its protective functions, the **LB1-LC03M13** also contributes to energy efficiency by preventing motor damage that could lead to costly repairs or premature replacement. By continuously monitoring the motor s thermal conditions, it helps maintain optimal operating temperatures, reducing energy waste associated with overheating. The relay s **precise tripping characteristics** also ensure that motors are protected from both **short-term overloads** (such as those caused by mechanical jams) and **long-term overheating** (resulting from sustained high loads), thereby extending the motor s operational lifespan. For applications requiring additional functionality, the LB1 series is compatible with **remote monitoring and control systems**, allowing for enhanced integration into larger automation setups.

In summary, the **Telemecanique LB1-LC03M13 Overload Relay (6.3A, 10A trip)** is a sophisticated yet practical solution for motor protection, offering a blend of **adjustable thermal overload protection, mechanical reliability, and ease of installation**. Whether used in a small workshop, a commercial facility, or an industrial plant, this overload relay provides peace of mind by ensuring that electrical motors operate within safe parameters, reducing the risk of unexpected failures and enhancing overall system efficiency. Its robust construction, user-friendly features, and compatibility with Schneider Electric s broader range of automation products make it an indispensable component for any electrical protection strategy.

### **Pros and Cons of buying a Telemecanique LB1-LC03M13 Overload Relay (6.3A, 10A Trip)**

#### **Pros:**

1. **Reliability and Brand Reputation** Telemecanique (now part of Schneider Electric) is a well-established manufacturer known for high-quality electrical protection components. Their overload relays are widely trusted in industrial and commercial applications for consistent performance.

2. **Compatibility with Common Motor Sizes** The **10A trip setting** is suitable for small to medium motors (typically up to 1.5 kW at 230V or 3.7 kW at 400V), making it a practical choice for single-phase or three-phase applications in HVAC, pumps, conveyors, and similar equipment.

3. **Thermal Protection** The relay provides **thermal overload protection**, preventing motor damage from sustained overcurrent conditions (e.g., mechanical jamming, voltage fluctuations, or overloads). This extends motor lifespan and reduces downtime.

4. **Easy Installation and Wiring** The **LB1 series** is designed for straightforward mounting on DIN rails and has a simple wiring interface, making it accessible for technicians with basic electrical knowledge.

5. **Adjustable Trip Settings (Optional)** While the **LC03M13** has a fixed 10A trip, Telemecanique offers other models in the LB1 series with **adjustable trip curves** (e.g., LC03M11 for 6.3A, LC03M14 for 12.5A), allowing flexibility for different motor sizes if needed.

6. **Compatibility with Circuit Breakers** It can be paired with **Schneider Electric circuit breakers** (e.g., Acti9, Masterpact) for coordinated protection, improving overall system safety.

7. **Long Lifespan** High-quality bimetallic elements in overload relays like this one are designed to endure millions of operations without significant degradation.

8. **Standardized Design** The LB1 series follows industry standards (IEC/EN), ensuring compatibility with other protection devices and compliance with safety regulations.

9. **Low Maintenance** Once installed correctly, these relays require minimal maintenance, primarily involving periodic inspection for corrosion or mechanical wear.

10. **Cost-Effective for Small Applications** For motors in the **6.3A 10A range**, this relay offers a balance between affordability and protection, avoiding the need for more expensive solutions.

---

#### **Cons:**

1. **Fixed Trip Setting** The **LC03M13** has a **non-adjustable 10A trip**, meaning it cannot be modified for motors requiring a different current rating. If the motor s full-load current is significantly below or above 10A, protection may be inadequate or cause unnecessary tripping.

2. **Limited Current Range** The relay is optimized for **small motors (up to 3.7 kW at 400V)**. For larger motors, a higher-rated overload relay (e.g., 16A, 20A, or 25A) would be necessary, which may not be compatible without additional components.

3. **No Electronic Trip Adjustment** Unlike some modern overload relays with **electronic trip curves**, this is a **mechanical bimetal relay**, which may not offer the same level of precision in trip characteristics (e.g., inverse time curves).

4. **Potential for False Tripping** If the motor has **high starting currents** (e.g., fan motors, pumps with high inertia), the relay might trip during startup unless properly coordinated with the circuit breaker.

5. **Replacement Cost** While the relay itself is reasonably priced, **replacing a faulty bimetal element** (if available) or the entire unit can add up over time, especially in high-usage environments.

6. **Limited Environmental Ratings** Standard LB1 relays are typically rated for **indoor use** (IP20). For harsh environments (e.g., dust, moisture, or extreme temperatures), a **higher IP-rated** or **explosion-proof** version may be required, increasing cost.

7. **Compatibility Issues with Non-Schneider Systems** While widely compatible, some legacy or non-Schneider systems may require **additional adapters or wiring modifications** for seamless integration.

8. **No Built-In Short-Circuit Protection** This relay **only protects against overloads**, not short circuits. For complete protection, it must be used **in conjunction with a circuit breaker** (e.g., a thermal-magnetic breaker).

9. **Aging of Bimetal Elements** Over time, bimetal elements can **lose sensitivity**, leading to delayed tripping or failure to protect. While rare, this is a potential long-term concern.

10. **Limited Availability of Spare Parts** As Telemecanique shifts focus to newer series (e.g., **Acti9, Masterpact**), finding **original spare parts** for older models like the LB1 may become difficult in the future.

---

### **Conclusion:**

The **Telemecanique LB1-LC03M13 (6.3A, 10A trip)** is a **reliable, cost-effective solution** for small motors in the **6.3A 10A range**, particularly in applications where **thermal overload protection** is the primary concern. Its **mechanical simplicity, brand reliability, and compatibility with Schneider systems** make it a strong choice for basic protection needs.

However, **limitations in adjustability, current range, and environmental resilience** mean it may not be ideal for **larger motors, high-starting-current applications, or harsh environments**. Additionally, its **fixed trip setting** requires careful motor sizing to avoid misapplication.

For **new installations or critical applications**, considering **electronic overload relays** (e.g., Schneider s **Acti9 series**) or **adjustable mechanical relays** (e.g., **LC03M11/14 variants**) may offer better flexibility. If budget and simplicity are priorities, the **LB1-LC03M13 remains a solid, proven choice** for small motor protection.

---

### **Recommendation:** - **Buy the LB1-LC03M13 if:**

- You need a **simple, reliable overload relay** for **small motors ( 3.7 kW at 400V)**.

- The motor s **full-load current is close to 10A** (within 10% for optimal protection).

- You are using **Schneider Electric circuit breakers** for coordinated protection.

- The application is in a **controlled indoor environment** (IP20).

- **Consider alternatives if:**

- The motor s **current rating is significantly below or above 10A** (e.g., 5A or 12.5A ).

- You need **adjustable trip settings** or **electronic trip curves**.

- The application involves **high starting currents, frequent starts/stops, or harsh conditions**.

- You require **short-circuit protection** (must pair with a breaker).

- Long-term **spare parts availability** is a concern (consider newer Schneider models).

- **For future-proofing**, explore:

- **Schneider Acti9 or Masterpact series** (electronic overload relays with adjustable curves).

- **Adjustable mechanical relays** (e.g., **LC03M11 for 6.3A, LC03M14 for 12.5A**).

- **Modular protection systems** if integrating with PLCs or advanced control panels.

If the **LB1-LC03M13 fits your motor s current rating and application**, it is a **practical and cost-effective purchase**. Otherwise, evaluate whether a **more flexible or higher-rated relay** would better serve your needs.

Details:

Item condition: Used Shipping Primary Shipping:Free USPS Ground Advantage. Telemecanique LB1-LC03M13 All Photos 6 images thumbnail to view Here are some overload relays. Technical Specifications, make Telemecanique, model LB1-LC03M13, trip current 6,3a - 10a. These are in clean functional and cosmetic shape.

LOCATION: C1405 BIN C-1405-A.

part #: lb1lc03m13 prices

  • $23.60-$98.99

specifications automationjack:

  • brand: Telemecanique
  • mpn: Lb1-lc03m13

returns automationjack:

  • method: Money back
  • paid by: Buyer
  • time: 30 Days
  • policy: Returns Accepted

payments automationjack:

  • other
  • wallet: Apple-pay
  • credit card: Visa

offer automationjack:

  • availability: In Stock
  • started: June 1, 2026
  • best offers: True
  • quantity: 3
  • sold: 0
  • options: Ship-to-home

shipping automationjack:

  • service: USPS Ground Advantage, UPS Ground, UPS Next Day Air
  • transit: 4-8 Days
  • carrier: USPS, UPS
  • class: Standard, One-day
  • cost: $0.00
  • type: Calculated

seller automationjack:

  • rating: 100.0%
  • # reviews: 21751
  • city: Laporte, Colorado

general automationjack:

  • Business Industrial > Industrial Automation Motion Controls > Other Automation Equipment
  • condition: Used
category: business & industrial > industrial automation motion controls > automation equipment, sku: 15900996190154881,
Telemecanique LB1-LC03M13 Is Similar To:
automationjack logo
5 offers $23.60–$98.99 USD
  • Used. Offer #1 priced at $34.25 + $0.00 shipping estimate = $34.25* total. Switches. Where Do You Get All This Stuff?.FREE SHIPPING
  • Used. Offer #2 priced at $23.60 + $13.70 shipping estimate = $37.30* total. +$13.70 shipping
  • New. Offer #3 priced at $98.99 + $0.00 shipping estimate = $98.99* total. Included: Overload Protection Module Assembly Manufacturer Part Number: LB1LC03M13.FREE SHIPPING
  • Used. Offer #4 priced at $150.00 + $20.00 shipping estimate = $170.00* total. Inventory #. View all photos.+$20.00 shipping
  • New. Offer #5 priced at $39.99 + $14.10 shipping estimate = $54.09* total. TELEMECANIQUE PROTECTION MODULE LB1 LC03M13.+$14.10 shipping

Copyright © automationjack.com