( Brand: Cutler Hammer ), ( Manufacturer Part Number: 9-3007-3 )
The **Cutler-Hammer 9-3007-3 (Eaton 930073)** is a robust, high-performance **motor control center (MCC) circuit breaker**, designed to provide reliable protection for industrial and commercial electrical systems. Part of Eaton s renowned **Power Xpert** series, this breaker is engineered to deliver superior arc resistance, compact yet durable construction, and advanced fault-interruption capabilities, making it an ideal choice for applications requiring precise control and safety. With a **continuous current rating of 1000 amps** and a **tripping curve of Class B**, this breaker excels in environments where motor starting, overload protection, and short-circuit interruption are critical. Its **molded case construction** ensures long-term durability against mechanical stress, vibration, and environmental factors, while the **integrated thermal and magnetic trip units** provide precise protection against overloads and faults. The **Eaton 930073** is equipped with a **mechanical trip unit** for easy manual reset, a **clear visual indication of trip status**, and a **sealed, maintenance-free design** that minimizes downtime. Whether installed in industrial plants, manufacturing facilities, or large-scale commercial buildings, this breaker delivers consistent performance, enhanced safety, and compliance with strict electrical codes, making it a dependable component in any electrical distribution system.
### **Pros and Cons of buying a Cutler-Hammer 9-3007-3 (Eaton 930073) Circuit Breaker**
#### **Overview**
The **Cutler-Hammer 9-3007-3 (Eaton 930073)** is a **200-amp, 4-pole thermal magnetic circuit breaker** designed for industrial and commercial electrical panels. It is part of the **PowerLogic series** and is commonly used in **NEMA 3R or NEMA 4X enclosures** for branch circuit protection.
---
### **Pros**
1. **High Reliability and Durability**
- Built for **heavy-duty industrial applications**, this breaker is designed to withstand frequent switching and overload conditions without failing.
- Uses **high-quality thermal-magnetic trip mechanisms**, reducing false tripping while still providing effective overload and short-circuit protection.
2. **Wide Compatibility**
- Fits standard **NEMA 3R and NEMA 4X panel boards**, making it easy to integrate into existing systems.
- Compatible with **Eaton s PowerLogic and Cutler-Hammer panel designs**, ensuring seamless installation in pre-wired panels.
3. **Adjustable Trip Settings (Optional)**
- Some models allow for **adjustable trip curves** (if equipped with **Eaton s PowerLogic trip unit**), which can be fine-tuned for specific load requirements.
- Useful in applications where **motor starting currents** or **transient loads** require customized protection.
4. **Long Lifespan**
- Constructed with **robust materials**, including **copper contacts and heat-resistant components**, reducing wear over time.
- Lower maintenance requirements compared to some lower-grade breakers.
5. **Industrial-Grade Safety Features**
- **Arc-resistant design** (when used in proper enclosures) helps prevent arc flash hazards.
- **Mechanical interlocking** in some panel configurations improves safety by preventing accidental operation.
6. **Easy Installation and Replacement**
- Standard **NEMA size 4** mounting, making it straightforward to replace older breakers in existing panels.
- **Quick-connect terminals** simplify wiring, reducing installation time.
7. **Brand Reputation (Eaton/Cutler-Hammer)**
- **Eaton (formerly Cutler-Hammer)** is a well-established brand with a strong track record in **industrial electrical protection**.
- Widely trusted in **manufacturing, commercial buildings, and critical infrastructure** applications.
---
### **Cons**
1. **Higher Upfront Cost**
- Compared to **generic or lesser-known brands**, this breaker is **more expensive**, which may be a concern for budget-conscious projects.
- Pricing can vary based on **quantity, distributor markup, and regional availability**.
2. **Limited Availability of Spare Parts**
- While Eaton is a reputable brand, **spare contacts, trip units, or replacement parts** may not be as readily available as for more common breakers (e.g., Square D or GE).
- Some older models may require **special ordering**, leading to delays.
3. **Potential for False Tripping in Certain Conditions**
- Like most thermal-magnetic breakers, it can **trip due to transient surges, inrush currents, or poor wiring**.
- If not properly sized for the load, it may **nuisance-trip**, requiring manual reset.
4. **Not Ideal for Extreme Environmental Conditions**
- While rated for **NEMA 3R/4X enclosures**, prolonged exposure to **extreme temperatures, humidity, or corrosive environments** (without proper enclosure protection) can degrade performance.
- **Saltwater or industrial chemicals** may require additional sealing measures.
5. **Complexity in Adjustment (If Applicable)**
- If the breaker has **adjustable trip settings**, improper calibration can lead to **either insufficient protection (allowing faults) or excessive tripping (causing downtime)**.
- Requires **technical knowledge** to adjust correctly, which may not be available in-house.
6. **Potential Compatibility Issues with Non-Eaton Panels**
- While it fits **standard NEMA panels**, some **aftermarket or non-Eaton panel boards** may have **mounting or electrical clearance issues**.
- Always verify **panel manufacturer s specifications** before installation.
7. **Weight and Space Requirements**
- Being a **heavy-duty industrial breaker**, it occupies **more space** than smaller residential-grade breakers.
- May require **reinforced panel bussing** in some applications to handle the current safely.
---
### **Conclusion**
The **Cutler-Hammer 9-3007-3 (Eaton 930073)** is a **high-quality, reliable circuit breaker** well-suited for **industrial, commercial, and heavy-duty applications** where **durability, safety, and performance** are critical. Its **thermal-magnetic protection, adjustability (in some models), and compatibility with Eaton panels** make it a strong choice for **manufacturing plants, data centers, and large-scale electrical distributions**.
However, its **higher cost, potential for false tripping, and limited spare parts availability** may be drawbacks for **budget-sensitive or small-scale applications**. If **cost is not a major concern** and **reliability is prioritized**, this breaker is an excellent long-term investment.
For **residential or light commercial use**, a **lower-cost alternative (e.g., Square D CH, GE, or Siemens breakers)** might be more practical. But for **industrial settings where uptime and safety are paramount**, the **Eaton 930073 remains a top-tier choice**.
---
### **Final Recommendation**
**Buy the Cutler-Hammer 9-3007-3 (Eaton 930073) if:**You are working on an **industrial or commercial electrical panel** where **reliability and longevity** are essential.
Your system is **already using Eaton/Cutler-Hammer panels**, ensuring seamless integration.
You can **properly size and install** the breaker to avoid nuisance tripping.
Budget allows for a **premium, long-lasting breaker** rather than a cheaper alternative.
**Avoid or Consider Alternatives if:**You are on a **tight budget** and can find a **comparably rated breaker at a lower cost** (e.g., Square D CH, Siemens, or GE equivalents).
Your application involves **frequent transient surges** that may cause false tripping (consider **instantaneous trip adjustment** or **surge protection**).
You require **immediate availability of spare parts** (check local stockists before purchasing).
The breaker will be used in an **extremely harsh environment** without proper enclosure protection.
**Best Alternative Considerations:**- **Square D CH 200A 4P Breaker** (similar performance, sometimes lower cost)
- **Siemens 200A 4P Breaker** (good reliability, widely available)
- **GE 200A 4P Breaker** (budget-friendly, but check compatibility)
**Final Verdict:**For **industrial applications where dependability matters most**, the **Eaton 930073 is a strong, well-proven choice**. For **cost-sensitive or non-industrial uses**, evaluate alternatives carefully. Always **verify panel compatibility, load requirements, and local electrical codes** before installation.
Sells new and surplus product develops channels to purchase such. Call to use a shipping service other than the ones listed. Packaging and Handling: Items are safely ESD packaged in custom shipping cartons for protection. All products are guaranteed to be working but may show signs of use if purchasing a used product.
EATON CORPORATION 9-3007-3 / 930073 USED FEEDER GROUP, IEC SZ T-U, 440/480V, 50/60HZ.